<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>22131</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: Focus went out of range %s %s adjustments
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>ThermoFlex</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Check to see that the head serial data cable is either disconnected from the head
or properly terminated.  Check that the head is properly installed on the drum,
and that all focus numbers are in range.  If neither of these actions eliminates
the problem, then the head will need to be replaced.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Retry image and call service.
</text></DescriptionText>
</OperatorAction>
<Cause>
The serial data cable is connected to the TFX head and not properly terminated
at the other end.
</Cause>
<Cause>
The head is not installed properly.
</Cause>
<Cause>
There is a hardware problem in the head.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:56 2008 PST
</Updated>
<Links>
</Links>
</Error>